Colorimetry:
Reference Standard: BS EN ISO/CIE 11664-4:2019 Test Results
l | a | b |
---|---|---|
98.1 | 0.1 | -0.8 |
a: Indicate the scale of color in the range of green (-) to red (+).
b: Indicate the scale of color in the range blue (-) to yellow (+).
l: Indicate the scale of color in the range black to white (0 to +100).
Note:
- Color Meter TES 135 was used for the test.
- The test was performed on the powder sample and the accuracy of the test depends on the uniformity of the powder.
Chemical Analysis
XRF According to: ASTM E 1621-21
Result of XRF:
Oxide | Weight% |
---|---|
Na2O | 0.03 |
CaO | 0.12 |
L.O.I | 4.42 |
MgO | 32.4 |
Fe2O3 | 0.25 |
Al2O3 | 0.32 |
K2O | 0.05 |
SiO2 | 61.97 |
SO3 | 0.44 |
Notes:
- The analysis depends on sampling and uniformity of sample.
- The result is semi quantitative.
- Because of L.O.I determination, the test sample was kept at 950°C for 1.5 hour.
CHEMICAL COMPOUND, SEM
Test Condition: 20 Kv, Tilt Angle: 0
Test Scope: RMRC-WI-550-102-01
Result of chemical compound on the sample, SEM:
Element | Weight % |
---|---|
O | 53.20 |
Mg | 20.36 |
Si | 26.44 |
Notes
- The result is semi quantitative.
- There is an error probability in detection of less than 0.4 % weight percent elements.

Spectra 1.spx
Element | Series | unn. C [wt.-%] | nors. C [wt.-%] | Atom. C [at.-%] |
---|---|---|---|---|
Оxygen | K serises | 47.22 | 53.20 | 65.15 |
Magnesian | K serises | 18.07 | 20.36 | 16.41 |
Silicon | K serises | 23.47 | 26.44 | 18.44 |
Total: 88.8% |

CERTIFICATE OF ANALYSIS
1398-6182
Element | Ag | Al | As | Ba | Be | Bi | Ca | Cd | Ce | Co | Cr | Cs | Cu | Dy | Er | Eu | Fe | Gd | Hf | In |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DI | 0.1 | 0.01 | 0.1 | 1 | 0.2 | 0.1 | 0.01 | 0.1 | 0.5 | 1 | 1 | 0.5 | 1 | 0.02 | 0.05 | 0.1 | 0.01 | 0.05 | 0.5 | 0.5 |
Unit | ppm | % | ppm | ppm | ppm | ppm | % | ppm | ppm | ppm | ppm | ppm | ppm | ppm | ppm | ppm | % | ppm | ppm | ppm |
Method | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS |
CO | ||||||||||||||||||||
CO | ||||||||||||||||||||
Golden Pack T-08 | <0.1 | 0.11 | <0.1 | 7 | 0.3 | 0.4 | 0.05 | <0.1 | <1 | 3.8 | <1 | <0.5 | 1 | 0.09 | 0.2 | <0.1 | 0.14 | 0.54 | 0.6 | <0.5 |
Element | K | La | Li | Lu | Mg | Mn | Mo | Na | Nb | Nd | Ni | P | Pb | Pr | Rb | S | Sb | Sc | Se | Si | Sm | Sn |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dl | 100 | 1 | 1 | 0.1 | 100 | 5 | 0.1 | 100 | 1 | 0.5 | 1 | 10 | 1 | 0.05 | 1 | 50 | 0.5 | 0.5 | 0.5 | 0.01 | 0.02 | 0.1 |
Unit | ppm | ppm | ppm | ppm | ppm | ppm | ppm | ppm | ppm | ppm | ppm | ppm | ppm | ppm | ppm | ppm | ppm | ppm | ppm | % | ppm | ppm |
Method | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS |
CO | ||||||||||||||||||||||
CO | ||||||||||||||||||||||
Golden Pack T-08 | <100 | 1 | <1 | <0.1 | 20.16% | <5 | <0.1 | 366 | <1 | 1.5 | 10 | 84 | <1 | 0.36 | 1 | <50 | <0.5 | <0.5 | 1.04 | 30.01 | <0.02 | 0.4 |
Element | Sr | Ta | Tb | Te | Th | Ti | Tl | Tm | U | V | W | Y | Yb | Zn | Zr |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DI | 1 | 0.1 | 0.1 | 0.1 | 0.1 | 10 | 0.1 | 0.1 | 0.1 | 1 | 1 | 0.5 | 0.05 | 1 | 5 |
Unit | ppm | ppm | ppm | ppm | ppm | ppm | ppm | ppm | ppm | ppm | ppm | ppm | ppm | ppm | ppm |
Method | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS | AFMS |
CO | |||||||||||||||
CO | |||||||||||||||
Golden Pack T-08 | <1 | 0.17 | 0.18 | 0.13 | 1.14 | <10 | <0.1 | <0.1 | 0.5 | 9 | <1 | <0.5 | <0.05 | <1 | <5 |
Standard Determination
The Sample contains Mg3Si4O10(OH)2 and it doesn’t contain asbestos.
Chemical Analysis, XRD
According to: BS EN 13925-1: 2008
Current: 30 mA Voltage: 40 kV Anode: Cu
2Ө: 2-100°
Step Size: 0.02 Counting time: 0.5 sec
Result of chemical compound, XRD:
Talc Mg3Si4O10(OH)2
Notes
- XRD graph is attached.
- The analysis depends on sampling and uniformity of sample.

Oil absorption test
Test method: ISO 787-5 (1980)
Test description:
1.0687 gr of a specimen was placed on the glass plate and the linseed oil was added slowly from the burette. The addition of oil continued until the formation of a smooth paste. Oil absorption is calculated according to the following formula:
Oil absorption (gr/100gr)=93V/m
V: 0.30 (ml)
Oil absorption: 26.11 (gr/100gr)
The test was done on sample with mesh No.20.
PH Determination
Result
- The sample’s pH in 10% of solution at 25°C was measured 5.3.
Temperature resistance test
Test Reference: Client’s Instructions
Test Description:
The sample was placed in the furnace and after rising temperature with an interval of 100° C, its appearance was checked visually.
Test Result:
The sample was melted at 1400° C.
Image of the sample