Colorimetry:
Refference Standard: BS EN ISO/CIE 11664-4:2019 Test Results
l | a | b |
---|---|---|
98.6 | 0.8 | -1.1 |
a: Indicate the scale of color in the range of green (-) to red (+).
b: Indicate the scale of color in the range blue (-) to yellow (+).
l: Indicate the scale of color in the range black to white (0 to +100).
Note:
- Color Meter TES 135 was used for the test.
- The test was performed on the powder sample and the accuracy of the test depends on the uniformity of the powder.
Chemical Analysis
According to: ASTM E 1621-21
Result of XRF:
Oxide | Weight% |
---|---|
Na2O | N.D |
CaO | 0.06 |
L.O.I | 4.5 |
MgO | 32.4 |
Fe2O3 | 0.12 |
Al2O3 | 0.1 |
K2O | N.D |
SiO2 | 62.82 |
SO3 | N.D |
Notes:
- The analysis depends on sampling and uniformity of sample.
- N.D=Not Detectable.
- The result is semi quantitative.
- Because of L.O.I determination, the test sample was kept at 950°C for 1.5 hour.
CHEMICAL COMPOUND, SEM
Test Condition: 20 Kv, Tilt Angle: 0
Test Scope: RMRC-WI-550-102-01
Result of chemical compound on the sample, SEM:
Element | Weight % |
---|---|
O | 52.97 |
Mg | 20.32 |
Si | 26.71 |
Notes
- The result is semi quantitative.
- There is an error probability in detection of less than 0.4 % weight percent elements.

Spectra: 2. spx
Element | Series | unn. C [wt.-%] | norm. C [wt.-%] | Atom. C [at.-%] |
---|---|---|---|---|
Оxygen | K serises | 48.5 | 52.97 | 64.94 |
Magnesian | K serises | 18.61 | 20.32 | 16.40 |
Silicon | K serises | 24.46 | 26.71 | 18.66 |
Total: 91.6% |

Analysis ICP-Mass
Result
Result of chemical analysis test:
Element | Weight % |
---|---|
Ag | <0.0001 |
Al | 0.0120 |
As | <0.0001 |
Ba | 0.0011 |
Bi | <0.0001 |
Be | <0.0001 |
B | 0.0021 |
Cd | <0.0001 |
Cr | <0.0001 |
Ce | <0.0001 |
Ca | 0.0810 |
Cu | 0.0014 |
Co | <0.0001 |
Dy | <0.0001 |
Eu | <0.0001 |
Er | <0.0001 |
Fe | 0.0540 |
Gd | <0.0001 |
Ga | <0.0001 |
Ge | <0.0001 |
Hf | <0.0001 |
Hg | <0.0001 |
Ho | <0.0001 |
In | <0.0001 |
K | 0.0057 |
Lu | <0.0001 |
Li | <0.0001 |
La | <0.0001 |
Mn | 0.0037 |
Mg | >0.5000 |
Mo | <0.0001 |
Nb | <0.0001 |
Ni | <0.0001 |
Na | <0.0001 |
Nd | <0.0001 |
Pt | <0.0001 |
Pd | <0.0001 |
Pb | 0.0280 |
P | 0.0250 |
Re | <0.0001 |
Rh | <0.0001 |
S | <0.0001 |
Sn | 0.0094 |
Sr | <0.0001 |
Se | <0.0001 |
Sm | <0.0001 |
Sb | <0.0001 |
Sc | <0.0001 |
Te | <0.0001 |
Ti | 0.0014 |
Ta | <0.0001 |
Tm | <0.0001 |
Th | <0.0001 |
Tb | <0.0001 |
Tl | <0.0001 |
U | <0.0001 |
V | 0.0002 |
W | 0.0022 |
Y | <0.0001 |
Yb | <0.0001 |
Zr | <0.0001 |
Zn | 0.2765 |
Element | Concentration(ppm) |
---|---|
Ag | <1 |
Al | 120 |
As | <1 |
Ba | 11 |
Bi | <1 |
Be | <1 |
B | 21 |
Cd | <1 |
Cr | <1 |
Ce | <1 |
Ca | 810 |
Cu | 14 |
Co | <1 |
Dy | <1 |
Eu | <1 |
Er | <1 |
Fe | 540 |
Gd | <1 |
Ga | <1 |
Ge | <1 |
Hf | <1 |
Hg | <1 |
Ho | <1 |
In | <1 |
K | 57 |
Lu | <1 |
Li | <1 |
La | <1 |
Mn | 37 |
Mg | >5000 |
Mo | <1 |
Nb | <1 |
Ni | <1 |
Na | <1 |
Nd | <1 |
Pt | <1 |
Pd | <1 |
Pb | 280 |
P | 250 |
Re | <1 |
Rh | <1 |
S | <1 |
Sn | 94 |
Sr | <1 |
Se | <1 |
Sm | <1 |
Sb | <1 |
Sc | <1 |
Te | <1 |
Ti | 14 |
Ta | <1 |
Tm | <1 |
Th | <1 |
Tb | <1 |
Tl | <1 |
U | <1 |
V | 2 |
W | 22 |
Y | <1 |
Yb | <1 |
Zr | <1 |
Zn | 2765 |
Standard Determination
The Sample contains Mg3Si4O10(OH)2 and it doesn’t contain asbestos.
Chemical Analysis, XRD
According to: BS EN 13925-1: 2008
Current: 30 mA Voltage: 40 kV Anode: Cu
2Ө: 2-100 Step Size: 0.02 Counting time: 0.5 sec
Result of chemical compound, XRD:
Talc Mg3Si4O10(OH)2
Notes
- XRD graph is attached.
- The analysis depends on sampling and uniformity of sample.

Oil absorption test
Test method: ISO 787-5 (1980)
Test description:
1.0034 gr of a specimen was placed on the glass plate and the linseed oil was added slowly from the burette. The addition of oil continued until the NILN in 11 consecutive years, formation of a smooth paste. Oil absorption is calculated according to the following formula:
Oil absorption (gr/100gr) = 93V / m
V: 0.40 (ml)
Oil absorption: 37.07 (gr/100gr)
* The test was done on sample with mesh No.20.
pH Determination
Result:
The sample’s pH in 10% of solution at 25°C was measured 5.5
Temperature resistance test
Test Reference: Client’s Instructions
Test Description:
The sample was placed in the furnace and after rising temperature with an interval of 100 °C, its appearance was checked visually.
Test Result:
The sample was melted at 1400 °C.
Image Of The Sample